Daily
P.M.:
A.
Check
the
Air
Filter
bowl
at
the
Dual
Pressuie
Regulator
and
drain
off
any
accumulated
water.
No
water
should
be
present
at
the
Air
Filter,
if
water
is
present,
refer
to
Page
3-005,
Step
c.
B.
Check
the
lubricators,
located
at
each
character's
trap
door
under
the
stage.
1.
If
any
water
is
present,
refer
to
Page
3-005,
Step
C.
2.
Fill
to
3/4
full
with
10
wt.
Non-Detergent
Oil.
See
page
3-003,
step
G,
for
filling
instructions.
C.
Lubricate,
check
over
and
tighten
one
character
daily.
Rotate
the
characters
and
keep
a
check
list
so
that
all
the
characters
are
checked
over
every
8
days.
Do
the
Sun
and
Moon
on
the
same
day
and
the
Spider
and
Baby
Bear
in
one
day.
1.
Lubricate
all
hinge
points
using
black
C.E.I.
lube,
e.g.
shoulders,
waist,
neck
pivot,
etc.
(Do
Not
disassemble
the
hinges
to
lubricate)
2.
Lubricate
all
theĀ·
Cylinders,
Piston
Shaft,
using
black
C.E.I.
lube.
Actuate
the
cylinders
and
check
for
a
smooth
and
complete
movement.
3.
Clean
any
loose
fur
and,
or
accumulated
dirt
from
cylinder
rods
and
guide
shafts,
wipe
away
any
excess
grease.
4.
Remove
the
latex
mask
and
clean
the
Eye
Balls
using
a
Household
type
cleaner
(Fantastic
or
409)
and
a
soft
clean
cloth.
Allow
the
eye
ball
to
dry
completely
before
reattaching
the
mask.
5.
Check
all
the
welded
joints
for
cracks.
6.
Tighten
any
loose
parts,
set
screws,
shaft
collars,
cap
screws,
nuts
and
bolts.
7.
Tighten
all
jam
nuts
on
cylinders.
If
any
jam
nuts
are
found
loose
refer
to
Pages
3-094
thru
3-135,
Critical
Adjustments,
to
check
the
les.
(SEE
DRAWING
BELOW)
JAM
NUT
D.
Set
up
the
Video
Adjustment
tape,
and
run
the
tape.
Run
the
character
through
the
show
without
sound.
Listen
and
watch
for
movements
being
out
of
sync
with
the
Video
Display,
mechanical
defects
or
Cosmetic
binding
i.e.
air
leaks,
squeaks,
rattles,
movements
not
working,
etc.
(See
Pages
1-010
thru
1-014
Video
Testing
Procedures
and
Charts)
E.
Verify
that
the
manager
is
aware
of
any
problems
that
do
exist.
F.
If
any
problems
do
exist
that
must
be
repaired
immediately,
refer
to
the
Trouble
Shooting
and,
or
Repair
Parts.
1-006