TROUBLE
SHOOTING
GUIDE
CHARACTER
AIR
SYSTEM
SYMPTOM:
MOVEMENT
NOT
FUNCTIONING
PROCEDURES:
1.
Manual
override
the
valve
on
the
valve
bank.
2.
Test
the
air
flow
at
the
quick
disconnect
plates,
by
manually
overriding
the
valve
and
check
for
loose
hose
connections
at
the
valve
bank,
flow
controls
and
quick
disconnect
plates.
3.
Check
cylinder
alignment
between
front
and
rear
mount,
and
check
cylinder
for
internal
leaks.
4.
Test
the
plumbing
harness,
by
manually
overriding
the
valve.
Check
plumbing
hose
connection
at
the
cylinder.
2-o09
RESULTS:
See
pages
1-011
thru
1-014
and
pages
3-003
and
3-004.
If
valve
shifts.
See
page
5-005.
If
valve
does
not
shift.
Repair
valve
in
question.
See
pages
3-06
thru
3-08.
No
air
-
Flow
controls
See
pages
3-008.
No
air
A/port,
override
is
activated.
No
air/B
port,
override
is
activated.
Air
flow
A/port,
override
is
not
activated.
No
air
B/port,
override
is
not
activated.
See
pages
3-006
thru
3-008
Loose
hose
connections.
See
page
3-009.
Internal
air
leak
or
physical
mechanical
damage
to
the
cylinder.
See
pages
3-009
thru
3-030.
Cut
or
crimped
air
line.
Loose
hose
connection
to
the
cylinder.
See
pages
3-009.