21
2. Set the <UsbMode> analog input join to the appropriate mode: 0d = Local (LEX)
or 1d = Remote (REX). For the DM-NVX-D80-IOAV, set USB Mode to 1d = Remote
(REX). For the DM-NVX-35x(C) to be paired with the DM-NVX-D80-IOAV, set
USB mode to 0d = Local (LEX).
3. Set the <UsbTransportMode> analog input join to the appropriate mode:
0d = Layer 2 (default) or 1d = Layer 3.
For Layer 2 transport, the <UsbLocalDeviceId_F> serial output join reports the
corresponding MAC address of each DM-NVX-35x(C) device. For Layer 3
transport, the <UsbLocalDeviceIpAddress_F> serial output join reports the
corresponding IP address of each DM-NVX-35x(C) device.
4. Do either of the following:
For Layer 2 transport:
a. Copy the MAC address (UsbLocalDeviceId) of the LEX device into the
<UsbRemoteDeviceId> serial input join on the REX device.
On the REX device, the <UsbRemoteDeviceId_F> serial output join reports
the MAC address of the LEX device to which the REX device is to be
paired.
b. Copy the MAC address (UsbLocalDeviceId) of the REX device into the
<UsbRemoteDeviceId> serial input join on the LEX device.
On the LEX device, the <UsbRemoteDeviceId_F> serial output join reports
the MAC address of the REX device to which the LEX device is to be
paired.
For Layer 3 transport:
a. Copy the IP address (UsbLocalDeviceIpAddress) of the LEX device into
the <UsbRemoteDeviceIpAddress> serial input join on the REX device.
On the REX device, the <UsbRemoteDeviceIpAddress_F> serial output join
reports the IP address of the LEX device to which the REX device is to be
paired.
b. Copy the IP address (UsbLocalDeviceIpAddress) of the REX device into
the <UsbRemoteDeviceIpAddress> serial input join on the LEX device.
On the LEX device, the <UsbRemoteDeviceIpAddress_F> serial output join
reports the IP address of the REX device to which the LEX device is to be
paired.
5. Do either of the following:
Trigger the <Pair> digital input join on each DM NVX device (LEX and REX).
Trigger the <AutomaticUSBPairingEnabled> digital input join on each DM
NVX device (LEX and REX).