22
If “Flooded” or “User-Defined” is selected in program 05, this
program can be set up.
31 Battery equalization voltage
default: 29.2V
Setting range is from 25.0V to
31.5V for 3.6K model and 48.0V to
62.0V for 7.8K model. Increment of
each click is 0.1V.
33 Battery equalized time
60min (default)
Setting range is from 5min to
900min. Increment of each click is
5min.
34 Battery equalized timeout
120min (default)
Setting range is from 5min to 900
min. Increment of each click is 5
min.
35 Equalization interval
30days (default)
Setting range is from 0 to 90 days.
Increment of each click is 1 day
36
Equalization activated
immediately
Enable
Disable (default)
If equalization function is enabled in program 30, this program can
be set up. If “Enable” is selected in this program, it’s to activate
battery equalization immediately and LCD main page will show
“
”. If “Disable” is selected, it will cancel equalization function
until next activated equalization time arrives based on program 35
setting. At this time, “ ” will not be shown in LCD main page.
37
Reset all stored data for PV
output load energy