CR-UCM Series Start-up and Install Check List
Start-up Sequence:
Turn Water on to unit (conrm ow from faucets)
Plug unit in and toggle On/O switch to the On posion.
Turn CO2 on at tank. (carb tank may need to be bled)
Water Filters, CR-24FC and CR-24FCP
Water On. Filters ushed via the ush valve and owing water.
Water pressure at/through water lter system above 50 psi and not dropping o.
All connecons leak free.
50 PSI water reducer valve installed aer water lter, poinng in the correct direcon.
CO2
CO2 hose from unit: are nut connecon on end of CO2 Hose ght to CR-3741 CO2 Regulator
(Be sure to use nylon washer supplied with Reg in ng).
CO2 Reg connected to CO2 tank (card board/plasc washer used) ght and leak free.
CO2 Tank Full, Opened all the way and Set to 75 PSI.
CBR tower:
Faucets ght to shank and posioned vercally. Free of leaks. Customer has faucet wrench.
Handles ght, front facing and labels are appropriate for water type.
Sparkling water; cold, carbonated and tastes clean and pure. (Run a few liters of water; is carb pump
cycling on and ow consistent without gassing out).
Sll Water: cold and consistent ow. Tastes clean and pure.
Flow adjustment on faucets set and knob ghtened down so ow rate cant change
Connecons to tower made using supplied Super Seal JG ngs from kit and leak free.
All exposed Hoses and Fings all wrapped in insulated foam tape.
Remote Chiller: Unit on.
Unit On and Plugged into a dedicated 120V outlet.
Cabinet properly venlated to handle BTU load of unit heat. Can fresh air draw in and hot air vent out.
Unit free of obstrucons around it and can vent. If using a Fan box, check that it is plugged in and running.
Unit posioned so Air Filter is accessible. If using a CR-ABUCM air bae, it is in place and sealing to vents.
Rear outlet connecons for trunkline (hoses and ngs) to tower wrapped in insulted tape and leak free.
Water Inlet connecon to unit leak free and not pinched o anywhere
Water Bath lled with water up to the white stand pipe.
Ice Bank formed on refrigeraon coils in water bath. Unit cycling on and o properly to maintain ice bank.
Unit will take 2 hours to form full ice bank aer inial start-up.
Carb pump cycling on for 7-14 seconds aer 1.5 liters of Sparking water is poured, and not screeching.
Agitator pump agitang bath water and pumping re-circ water through the trunkline.
Notes: