Charging the high-voltage battery
Troubleshooting
Fault in the high voltage system
The warning lamp lights up red. A message is
displayed in this regard.
There is a fault in the high voltage system. The
high voltage components may be damaged
›››
.
It is not possible to charge the high-voltage
battery.
●
The vehicle must be parked in a safe
place. Park the vehicle outdoors as soon as it is
possible and safe to do so.
●
Switch o the drive system.
●
Seek professional assistance.
and Danger of re!
The warning lamp
lights up red and is dis-
played along with with a text message on the
instrument cluster accompanied by a continu-
ous audible warning.
●
Stop driving! Get out of the vehicle and
notify the re department immediately.
●
The high voltage battery temperature is too
high .
●
If the message is hidden, the warning lamp
remains visible
.
The audible warning can only be turned o
by a qualied workshop. CUPRA recommends
that you visit an oicial dealer.
WARNING
If there is a risk of
re in the high-voltage
battery, toxic gases may escape or compo-
nents may be released from the high voltage
battery. There is a risk of serious injury, burns
or lethal electric shocks.
●
Park the vehicle safely as soon as possible
›››page65, Behaviour in the event of an
accident or re.
●
Get out of the vehicle and keep a safe dis-
tance away from it.
●
Call the re department immediately.
Deep discharge of the high-voltage bat-
tery due to prolonged parking time
The control lamp lights up red. A message is
displayed.
The high-voltage battery can be damaged if,
for example, the vehicle is not used for a long
time.
●
Charge the high-voltage battery immedi-
ately.
High voltage battery discharged
The control lamp switches on yellow. A mes-
sage is displayed.
●
Charge the high-voltage battery immedi-
ately.
Low state of charge in the high-voltage
battery
The control lamp switches on yellow. A mes-
sage is displayed showing the remaining range.
The high-voltage battery charge has reached
the reserve level.
●
Charge the high-voltage battery.
Range calculation fault
The control lamp switches on yellow. A mes-
sage is displayed.
There is a fault in the range calculation. Con-
tact a specialised workshop.
The charging process is not possible or has
been paused
The charging process indicator located next to
the charging socket lights up red.
Before visiting a specialist workshop, you can
try the following solutions:
●
Plug the charging cable back in.
●
Check that the charging connector is plug-
ged in correctly.
●
Check if a fault is displayed on the charging
station or, depending on the equipment, on
the charging cable protection device.
If the fault cannot be rectied, contact a spe-
cialist workshop immediately.