6. Constant tables
Constant
NO
Name Description
Setting
value
Factory
setting
Change
during
operation
Com.
add.
Page
Cd-75
Low voltage
prevention active
point
220V series=220V
380V series =380V
440V series =440V
155󲕏500
By
spec.
No 541 P81
Cd-76
Speed search
active current
When Cd28=2 is valid (please reduce setting value
when unable to restart
0󲕏200% 120% No 542 P83
Cd-77
Speed search
deceleration time
When Cd28=2 is valid 0.1󲕏10.0 2.0S No 543 P83
Cd-78
Speed search
waiting time
When Cd28=2 is valid 0.0󲕏20.0 0.2S No 544 P83
Cd-79
Momentary power
loss direction
0: Invalid
Valid, restart when power recovered in time of
(Cd80), detect low voltage of master power when
exceeded.
Movement of CPU is valid, restart when power
recovered (Cd80 will not be considered)
0󲕏2 0 No 545 P85
Cd-80
Momentary
power loss boost
time
Restart valid time limit when set Cd79=1 0󲕏2.0S 0.1S No 546 P85
Cd-81
Output voltage
recover time
From 0V to recover is time of maximum output
voltage when set restart
0.1󲕏20.0 3S No 647 P85
Cd-82
Overheating
forecast
detection level
Set Cd84 as 100% for level of detecting overheating
forecast for inverter
50󲕏100 90% No 548 P86
Cd-83
Motion when
overheating
forecast detection
0: Deceleration stop
1: Coast stop
2: Emergency stop
3: Continuous operation
0󲕏3 3 No 549 P86
Cd-84
Temperature
protection level
Set as unit for detecting level of inverter
overheating
Software protection is invalid when set 100℃
(OH is only hardare protection)
50󲕏100 85℃ No 550 P86
Cd-85
Current
hysteresis range
Set hysteresis range when relay and DO (Cd47、
Cd48) current detected
2󲕏20 2% Yes 551 P56
Cd-86
Current detect
level
Set current detect level when current detected 30󲕏150 100% Yes 552 P56
Cd-87
Analog output
filter time
Set filter time of analog output termainal to
eliminate the noise in effect.
Input reaction will become slow.
1󲕏
1000
5ms Yes 553 P50
Cd-88
Analog output 1
(FM) bias
Set voltage bias value of operation frequency analog
output, 10V is 100%。
±10.0% 0.0% Yes 554 P50

Table of Contents