53
◆Multi-step speeds frequency command
Description: Set by external terminals S1S6 and switch every step speed. Each step speed will not be
interference, the value never exceeds the maximum range.
Cd12= 2
nd
step frequency setting
Cd13= 3
rd
step frequency setting
Cd14= 4
th
step frequency setting
Cd40= 5
th
step frequency setting
Cd41= 6
th
step frequency setting
Cd42= 7
th
step frequency setting
Cd43= 8
th
step frequency setting
9. Output/ input terminals ■
Constant
No.
Constant name Settable range Factory setting
Change during
operation
Cd12 Frequency command 2 0.00400.00 20.00 O
Cd13 Frequency command 3 0.00400.00 30.00 O
Cd14 Frequency command 4 0.00400.00 40.00 O
Cd40 Frequency command 5 0.00400.00 45.00 O
Cd41 Frequency command 6 0.00400.00 50.00 O
Cd42 Frequency command 7 0.00400.00 55.00 O
Cd43 Frequency command 8 0.00400.00 60.00 O