74
13. MODBUS communication■
Constant No. Constant name Settable range Factory setting
Change during
operation
CE72
Communication
respond wating time
2󲕏65 2ms X
Description:When inverter receive a data, it will send the response data after CE72 time, it is used mainly when Master
process speed slower or TE single delay time of two wires communication.
Constant No. Constant name Settable range Factory setting
Change during
operation
CE74
Parity bit check 0󲕏2 0
X
Description:Setting value
0: disable 1: even parity bit 2: odd parity bit
MODBUS communication command
Function Data Setting MODBUS Address
FR 1
RR 3
Operation command
(d1-09)
STOP 4
72
MODBUS communication command
Function Data Setting MODBUS Address
Stand by 12
Forward 3
Reverse 15
Forward standing by 1
Reverse standing by 13
Forward is modified to reverse 5
Operation status
(d1-08)
Reverse is modified to forward 7
71