Adjust and Function Specification
Note: Apply to multi-speed setting external control is required for operation control
mode (e.g. Cd04=1), and it is also required to set Cd59 for activating common
terminal 4.
External
terminal
Name
Selective speed
2 3 4 5 6 7 8
Terminal 5
○ ○ ○ ○
Terminal 3
○ ○ ○ ○
Terminal 4
○ ○ ○ ○
○: stands for external terminal to put in.
§Cd44 Stop mode (Settable range 0-2)
Cd44=0 Deceleration stop
Cd44=1 Free run stop
Cd44=2 Free run stop, but restart after the deceleration time is reached,
deceleration time is set by Cd11.
§Cd45 Frequency detect level (Settable range 0.5-240)
This function is only available when RELAY output terminal Cd47=6 or
Cd48=6, and Cd45 is assigned.
HZ
OUTPUT
CD45
FA-FC
TIME
OPEN
CLOSE
TIME