Cybex 750A/750AT Arc Trainer Service Manual
Service
Page 4-28
ERROR 38 - INCLINE TIMEOUT
Note dashes in incline
window and no response
from incline. ERROR 38
present in log. Restart
unit.
Does the error
reoccur after restart?
Check battery voltage in
diagnostic mode. Voltage
needs to be above 12.5
VDC in order for incline to
function properly.
Yes
Does the battery
check out properly?
Yes
In diagnostic mode.
operate incline. note the
movement and position of
the incline.
Does the incline
move properly?
No
Recalibrate the incline
system.
Yes
Charge or replace
battery.
No
Completed.
No
Replace incline
motor.Recalibrate incline.
Does the incline
calibrate properly?
Yes
No