EasyManua.ls Logo

CYP AU-A300-HBT - RS-232 Communication Pinout

CYP AU-A300-HBT
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
5
12
LINE IN: Connect from audio device with 3.5ø pone jack for stereo
audio signal input.
13
IR IN: Connect the IR Extender for IR signal reception. Ensure
that remote being used is within the direct line-of-sight of the
equipment to be controlled.
14
IR OUT: Connect to IR Blaster for IR signal transmission. Place the IR
Blaster indirect line-of-sight of the equipment to be controlled.
15
DC 24V: Plug the 24V DC power supply into the unit and connect
the adaptor to an AC outlet.
6.3 RS-232 Pin Assignment
Remote Control
PIN Assignment PIN Assignment
1 NC 1 NC
2 Tx 2 Rx
3 Rx 3 Tx
4 NC 4 NC
5 GND 5 GND
6 NC 6 NC
7 NC 7 NC
8 NC 8 NC
9 NC 9 NC
Baud Rate: 115200bps
Data bit: 8 bits
Parity: None
Flow Control: None
Stop Bit: 1