EasyManua.ls Logo

CYP PU-507RX-SCD - Page 12

CYP PU-507RX-SCD
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
COMMAND DESCRIPTION
S SATURATION 0~60 Sets the numerical value for the
SATURATION setting (0~60)
R SATURATION Reports the numerical value for the
SATURATION setting (0~60)
S SHARPNESS 0~30 Sets the numerical value for the
SHARPNESS setting (0~30)
R SHARPNESS Reports the numerical value for the
SHARPNESS setting (0~30)
S NR 0~3 0=OFF 2=MIDDLE
1=LOW 3=HIGH
R NR Reports the numerical equivalent for the
NOISE REDUCTION setting (as listed above)
S AUDIO DELAY 0~3 0=OFF 2=110ms
1=40ms 3=150ms
R AUDIO DELAY Reports the numeric equivalent for AUDIO
DELAY setting (as listed above)
S AUDIO MUTE 0/1 0=ON 1=MUTE
R AUDIO MUTE Reports the numeric equivalent for AUDIO
MUTE setting (as listed above)
S KEY LOCK 0/1 0=ENABLE 1=DISABLE
R KEY LOCK Reports the numeric equivalent for KEY
LOCK setting (as listed above)
FW Checks the FIRMWARE version
S RESET 1 Sets the numerical equivalent for the RESET
setting (as left)
Note:
1. RS-232 commands will not execute unless followed with carriage return
and LF (Line Feed).
2. Commands are case-insensitive.
3. Resolutions 1~16 are RGB encoded and 17~25 are YUV encoded.
4. Digital audio supports LPCM 2CH only, please ensure the source input audio
is set to send LPCM 2CH audio in order to avoid unwanted audio noise.