- Smoke Jumper CYPRES 2 User’s Guide - page 25
for the Smoke Jumper CYPRES 2 excluding the ripcord housing for the activation handle:
Length, width, height of the processing unit: ..................................................approx. 85 x 43 x 32 mm
Length, width, height of the control unit: ......................................................approx. 65 x 18 x 6,5 mm
Length, diameter of the release unit: .........................................................................approx. 43 x 8 mm
Cable length of the release unit (including release unit): ............................................ approx. 500 mm
Cable length of control unit: ..........................................................can vary, standard approx. 670 mm
Volume ............................................................................................................ standard approx. 139 cm³
Weight: ....................................................................................................... standard approx. 182 grams
Activation window: .................................................. approx. 1.800 to 2.600 feet below arming altitude
Activation speed: ......................................................................................... approx. > 78 mph (35 m/s)
Storage temperature: .............................................................................................. +71° to -25° Celsius
Storage pressure: .................................................................... 200 to 1070 hPa ( 5,906 to 31,597 In.Hg)
Working temperature: ......................................................................................... +63° to -20° Celsius *
Maximum allowable humidity: ........................................................................ up to 98 % rel. humidity
Operating range below / above sea level: ................... -1500 feet to +17,000 feet (-500 m to +5000 m)
Functioning period: ............................................................................................. 2 hours from initiating
Maintenance: ..................................................................... 4 and 8 years from date of manufacture***
Power supply: .......................................................................................................... lifetime warranty**
Lifetime Warranty Period:..........................................................12.5 years from date of manufacture**
* These temperature limits do not mean the outside (ambient) temperatures but rather temperatures inside the processing
unit. Therefore, these limits won‘t have any meaning until the processing unit itself has reached the temperatures
in question. In actual fact, these limits will rarely be reached due to the mandatory location of the CYPRES in the
reserve container, and the insulating properties of the nylon pocket and parachute canopies.
** If required maintenance has been performed.
*** Anticipated, according to the present knowledge base.
12. Technical Data