Loading...
- Smoke Jumper CYPRES 2 User’s Guide - page 9
wait!
click
wait!
wait!
click click
self-test and
calibration
unit
switched on
click
light
appears
light
appears
light
appears
The push button on the control unit should be
pressed with the ngertip alone; please do not use
a ngernail or any object. Use a short clicking ac-
tion in the middle of the button. You should fa-
miliarize yourself with switching Smoke Jumper
CYPRES 2 on to be able to do the functioning
test.
With this Smoke Jumper CYPRES 2, you can use
the control unit only to check the operativeness.
Nothing else.
Do the operativeness check prior to every rst
jump of a day.
2. How to handle the Smoke Jumper CYPRES 2
2.1 How to deal with the control unit
The functioning test of the Smoke Jumper
CYPRES 2 is initiated by pressing the push but-
ton four times with very short clicks. Start the
switch-on cycle by clicking the button once. After
approx. one second, the red LED-light will glow.
You must acknowledge the red light immedi-
ately by clicking the button again. This sequence
- a click following appearance of the red light -
will be repeated two more times. After a total of
four clicks, Smoke Jumper CYPRES 2 goes into
self-test mode. If you do not act promptly after
seeing the LEDlight, or if you push the button to
soon, Smoke Jumper CYPRES 2 will ignore the