DES-1210-52/ME L2 Metro Ethernet Switch CLI Reference Guide
404
<macaddr> | 802.1p <value (0-7)> | ethernet_type <hex (0x0-
0xffff)>} | ip {source_ip <ipaddr> | destination_ip <ipaddr> |
dscp <value (0-63)> | [icmp {type <value (0-255)> code <value
(0-255)> } | igmp {type <value (0-255)>} | tcp {src_port <value (0-
65535)> | dst_port <value (0-65535)> | urg | ack | psh | rst | syn |
fin} | udp {src_port <value (0-65535)> | dst_port <value (0-
65535)> | protocol_id <value(0-255)>] | ipv6 {class | source_ipv6
<ipv6addr> | destination_ipv6 <ipv6addr>} [port [<portlist> | all]
[permit | deny]] delete access_id <value (1-5)>]
Description
The config cpu_access_profile command configures the settings
of cpu access profiles.
Parameters
profile_id <value 1-3> Specifies the cpu access profile to be
configured.
[add | delete] Add or delete the profile id.
access_id [<value 1-5> | auto_assign] Specifies the access id
value or use auto assign.
ethernet Specifies that the Switch examine only the layer 2 part of
each packet to determine if it is to be filtered or forwarded based on
one or more of the following:
802.1p <value 0-7> Specifies the 802.1p value. The range
is between 0 and 7.
destination_mac <macaddrf> Specifies the destination
MAC address.
ethernet_type Specifies the Ethernet type mask.
<portlist> Specifies the port or ports to be configured.
source_mac <macaddr> Specifies the source MAC
address.
vlan <vlanid 1-4094> Specifies the VLAN id.
ip Specifies that the Switch examine the IP fields in each packet to
determine if it will be either forwarded or filtered based on one or
more of the following:
destination_ip <ip_addr> Specifies the destination IP
address.
dscp <value 0-63> Specifies the DSCP value.
icmp Specifies that the Switch examines the Protocol field in
each frame’s IP header , and that the value must be 1 (Internet
Control Message Protocol- ICMP) for the action to take place.
code <value 0-255> Specifies that the Switch examine
each frame’s ICMP code field.
type <value 0-255> Specifies that the Switch examine each
frame’s ICMP Type field.
igmp Specifies that the Switch examine each frame’s protocol
field and it must be 2 (Internet Group Management Protocol-
IGMP) for the action to take place.
igmp_type <value 0-255> Specifies the IGMP type.
<portlist> Specifies the port or ports to be configured.
protocol_id <value 0-255> Specifies the protocol id.
source_ip <ip_addr> Specifies that the cpu access profile applies
only to packets with this source IP address.
Tcp Specifies that the Switch examines each frames protocol
field and its value must be 6 (Transmission Control Protocol-
TCP) for the action to take place
dst_port <value 0-65535> Specifies that the cpu access