DGS-1100-06/ME Metro Ethernet Managed Switch CLI Reference Guide
115
Success!
DGS-1100-06/ME:5#
disable rmon
Purpose
To disable remote monitoring (RMON) status for the SNMP function.
Syntax
disable rmon
Description
The disable rmon command disables remote monitoring (RMON)
status for the SNMP function on the Switch.
Parameters
None.
Restrictions
Only Administrator or operator-level users can issue this command.
Example usage:
To disable the RMON feature on the Switch:
DGS-1100-06/ME:5#disable rmon
Command: disable rmon
Success!
DGS-1100-06/ME:5#
create rmon alarm
Purpose
To allow the user to configure the network alarms. Network alarms
occur when a network problem, or event, is detected.
Syntax
create rmon alarm <alarm_index 1-65535> <OID_variable 255>
<interval 1-2147482647> [absolute | delta] rising-threshold
<value 0-2147483647> <rising_event_index 1-65535> falling-
threshold <value 0-2147483647> <falling_event_index 1-65535>
{[owner <owner_string 127>]}
Description
The create rmon alarm command allows the user to configure the
network alarms. Network alarms occur when a network problem, or
event, is detected.
Parameters
<alarm_index> Specifies the alarm number.
<OID_variable 255> Specifies the MIB variable value.
<interval 1-2147482647> Specifies the alarm interval time in
seconds.
[absolute | delta] − Specifies the sampling method for the selected
variable and comparing the value against the thresholds. The
possible values are absolute and delta:
absolute Compares the values directly with the thresholds
at the end of the sampling interval.
delta Subtracts the last sampled value from the current
value. The difference in the values is compared to the
threshold.
rising-threshold <value 0-2147483647> Specifies the rising
counter value that triggers the rising threshold alarm.