5 Configuration D-Link DGS-1100-06/ME User Manual
Figure 5.118 - Monitoring > Errors > Received (RX) (line graph)
To view the Received Error Packets Table, click the link View Table, which will show the following table:
Figure 5.119 - Monitoring > Errors > Received (RX) (table)
The following fields can be set or viewed:
Time Interval: Select the desired setting between 1s and 60s, where “s” stands for seconds. The default
value is one second.
Record Number: Select number of times the Switch will be polled between 20 and 200. The default value is
200.
CRC Align: Counts otherwise valid packets that did not end on a byte (octet) boundary.
UnderSize: The number of packets detected that are less that the minimum permitted packets size of 64
bytes and have a good CRC. Undersize packets usually indicate collision fragments, a normal network
occurrence.
OverSize: Counts packets received that were longer that 1518 octets, or if a VLAN frame is 1522 octets, and
less that the MAX_PKT_LEN. Internally, MAX_PKT_LEN is equal to 1522.