DGS-3000 Series Layer 2 Managed Gigabit Switch CLI Reference Guide
98
Example
To configure a “two rate, three color” flow meter:
DGS-3000-26TC:admin#config flow_meter profile_id 1 access_id 1 tr_tcm cir 1000
cbs 2000 pir 2000 pbs 2000 color_blind conform permit counter enable exceed
permit replace_dscp 60 counter enable violate drop
Command: config flow_meter profile_id 1 access_id 1 tr_tcm cir 1000 cbs 2000
pir 2000 pbs 2000 color_blind conform permit counter enable exceed permit
replace_dscp 60 counter enable violate drop
Success.
DGS-3000-26TC:admin#
6-6 show flow_meter
Description
This command is used to display the flow-based metering (ACL Flow Metering) configuration.
Format
show flow_meter {[profile_id <value 1-512> | profile_name <name 32>] {access_id <value 1-
256>}}
Parameters
profile_id - (Optional) Specifies the profile ID.
<value 1-512> - Enter the profile ID used here. This value must be between 1 and 512.
profile_name - (Optional) Specifies the name of the profile.
<name 32> - Enter the profile name used here. The maximum length is 32 characters.
access_id - (Optional) Specifies the access ID.
<value 1-256> - Enter the access ID used here. This value must be between 1 and 256.
Restrictions
None.
Example
To display the flow metering configuration:

Table of Contents