DXS-3326GSR Gigabit Layer 3 Switch
Appendix A
Technical Specifications
Physical and Environmental
AC Input & External
Redundant Power Supply
100 – 120; 200 - 240 VAC, 50/60 Hz (internal universal power supply)
Power Consumption 66 watts maximum
DC Fans 2 built-in 40 x 40 x10 mm fans
Operating Temperature 0 to 40 degrees Celsius
Storage Temperature -25 to 55 degrees Celsius
Humidity Operating: 5% to 95% RH non-condensing
Storage: 0% to 95% RH non-condensing
Dimensions 445 mm x 430 mm x 45 mm
Weight 5.5 kg
EMC
FCC Part 15 Class A / IECES-003 Class (Canada)
EN55022 Class A / EN55024
Safety CSA International
General
Standards
IEEE 802.3u 100BASE-TX Fast Ethernet
IEEE 802.3ab 1000BASE-T Gigabit Ethernet
IEEE 802.1D Spanning Tree
IEEE 802.1W Rapid Spanning Tree
IEEE 802.1 P/Q VLAN
IEEE 802.1p Priority Queues
IEEE 802.3ad Link Aggregation Control
IEEE 802.3x Full-duplex Flow Control
IEEE 802.3 Nway auto-negotiation
Protocols
CSMA/CD
Data Transfer Rates
Ethernet
Fast Ethernet
Gigabit Ethernet
Half duplex Full duplex
10 Mbps 20 Mbps
100 Mbps 200 Mbps
2000 Mbps (Full duplex only)
Topology
Star
Network Cables
10BASE-T
UTP Category 3, 4, 5 (100 meters max.)
261