EasyManua.ls Logo

DADISICK GFL-F Series - User Manual

Default Icon
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User manual for GFL-F series
laser ranging sensors
Warn
The light source of this product uses visible semiconductor lasers. It is prohibited
to directly or indirectly reect the laser beam from the reecting object into the eye.
If the laser beam enters the eyes, it may pose a risk of blindness.
This product does not have an explosion-proof structure. Prohibit use in
ammable, explosive gas or explosive liquid environments.
Do not disassemble or modify this product as it is not designed to automatically
turn o laser emission when the body is opened. If the client disassembles or modies
this product without authorization, it may cause personal inju, re, or electric shock
hazards.
The use of controls, adjustments, or operational procedures beyond those
specied here may result in hazardous radiation leaks.
Reminded
It is ve dangerous to wire, connect/disconnect inteaces when the power is
turned on. Please make sure to turn o the power before operation.
Installation in the following locations may cause malfunctions:
1. A place covered with dust or steam;
2. Places where corrosive gases can be generated;
3. A place that will directly receive splashed water or oil;
4. Places subjected to severe vibration or impact.
This product is not suitable for outdoor use.
Do not use this sensor in an unstable state sholy after the power is turned on
(approximately 15 minutes of warm-up time)
If it is necessato use a switching power regulator, please ground the grounding
terminal. Do not connect to high-voltage cables or power lines. Operation failure will
lead to induction or damage faults, as each product has dierences, so there may be
slight dierences in the detection characteristics of the workpiece.
Do not use this product in water.
Please do not disassemble, repair, or modify this product without authorization, as
it may cause electric shock, re, or inju to the human body.
Wipe o dust on the transmitting or receiving components to maintain proper
detection. Avoid direct impact of external objects on this product.
Operate within the rated range.
This product cannot be used as a safety device to protect the human body.
Dimensions
Wiring method
Technical Parameters
NPN+Analog+RS485
PNP+Analog+RS485
+ V
Brown
Pink
External
Input
Black
Control
Output
External
Input
Blue
0 V
+
-
12V-24V DC
±10%
The main circuit
AGND
White
Yellow
Gray
Analog
Output
Shield
Analog Ground
AGND
Analog
Input
Device
RS485(A+)
RS485(B-)
The main circuit
AGND
+ V
Brown
Pink
Black
Control
Output
Blue
0 V
External
Input
Gray
Analog
Output
Shield
Analog Ground
AGND
White
Yellow
RS485(A+)
RS485(B-)
Analog
Input
Device
External
Input
12V-24V DC
±10%
+
-
load
load
★: Indicates the measurement distance. In harsh environments, such as when the sunlight is too strong, the ambient
temperature uctuates too much, and the reective suace is dark, the measurement results will have larger errors. In
this case, the use of a target reective plate will be better.
Resolution
Measurement error
Laser type
Voltage
Current consumption
1mm
+(2mm+d*1/10,000)★
Red semiconductor laser Class II laser 655+10nm<1mW
12V-24VDC+10% pulsation P-P10%
50mA @24V
NPN or PNP open drain output
Open drain collector transistor output
Maximum current:50mA
Applied voltage: less than 30V DC
Residual voltage: less than 1.5V
Leakage current: less than 0.1mA
Control output
Output action
Sho circuit protection
Analog voltage output
Analog current output
Reaction time
External input
Protective structure
Operating temperature
Storage temperature
Working humidity
Use ambient illumination
Use elevation
Cable
Material
Quality
Normally open/normally closed can be switched
Automatic recove type
Output range: 0-5V (alarm: 5.2V) Output impedance: 100Ω
Output range: 4-20mA (alarm: 0mA) Output impedance: 300Ω max
50-200ms
NPN contactless input
IP67
-10C~+45℃ (be careful not to condense or freeze)
-20℃~+60℃
35%~85%RH
Incandescent lamp: light receiving suace illumination below 3000lux
Below 2000m
With 8-core composite cable 2m
Aluminum pas
About 150g
Item
Model
NPN+analog+485
PNP+analog+485
Measure distance
GFL-F100NM-485
GFL-F100PM-485
GFL-F200NM-485
GFL-F200PM-485
0.1-1m 0.1-2m
GFL-F500NM-485
GFL-F500PM-485
0.1-5m
Item
Model
NPN+analog+485
PNP+analog+485
Measure distance
GFL-FM10NM-485
GFL-FM10PM-485
GFL-FM20NM-485
GFL-FM20PM-485
0.1-10m 0.1-20m
GFL-FM50NM-485
GFL-FM50PM-485
0.1-50m
Display and Buttons
Threshold setting
Output indicator light
The current value
Learning key
+/options
-/options
Set up
Question and Answer IconNeed help?

Do you have a question about the DADISICK GFL-F Series and is the answer not in the manual?

DADISICK GFL-F Series Specifications

General IconGeneral
BrandDADISICK
ModelGFL-F Series
CategorySecurity Sensors
LanguageEnglish