29
5-10. Errors in Temperature Sensor
1) H1 Error - Open/Short error in Dry temperature sensor (Available for COMBO model only)
1 The Dry temperature sensor fails to work or is not properly connected.
2 The error warning is sounded for 10 seconds every 10 minutes.
3 If the Power button is turned off and on, the error display disappears.
2) H2 Error - Open/Short error in washer temperature sensor
1 The washer temperature sensor fails to work or is not properly connected.
2 The error warning is sounded for 10 seconds every 10 minutes.
3 If the Power button is turned off and on, the error display disappears.
3) H4 Error - Overheated washer temperature sensor
1 The sensor temperature turns out to be 125°C or higher.
2 If the Power button is turned off and on, the error display disappears.
4) H5 Error - Error in water temperature for Delicate program
1 The water temperature is 45°C or higher in the Delicate program. (The error occurs during operation only
when the tub contains water)
2 If the Power button is turned off and on, the error display disappears.
5) H6 Error - Malfunction of water heater
1 The water temperature fails to rise by 2°C within 30 minutes after the heater starts running.
2 If the Power button is turned off and on, the error display disappears.
6) H8 Error - Overheated water heater
1 The water temperature rises by 6°C or more within 30 seconds after the heater starts running due to the lack
of water in tub or other reasons.
2 The water heater doesn't operate although it is functional. The washer is running with the heater turned off.