51
1) Specifications
4. Specifications, Defect Inspection, and Repairs of Heater
1. Heater Washer
Temperature Fuse of Water Heater (184 °C Cutoff Type)
• If the heater is running without water due to a malfunction in water level sensor and other defects, it may cause
fire. The inter temperature fuse is designed to be cut off about a minute after overheating to prevent such
problems.
• The water heater must be used in water.
2. Heater Dry
• The heater work in the followed air flow at the Max, temperature of 600℃. The temperature in the sealing area
should not exceed 110 ℃.
Water Heater Dry HeaterWater Temperature Sensor
(Heater Washer) (Heater Dry)
Category
Specifications
Note
Heater Washer Heater Dry
MAKER DONGHAI DONGHAI
Voltage 230V 220V
Power 1400W ± 5% 1050W± 5%
Resistance 37.78 Ω 45.2 Ω
Power Density 11.9W/㎠ 2.25W/㎠
Temperature Fuse 184℃ (In Heater) 128℃
Thermistor Included in Heater NOT Included
Materials SUS304 INCOLOY800
MAX. Temperature 100℃ (In water) 600℃
Part Code 66127-0001504-00 66127-0002200-00
MINI 2.0_COMBO,WASH_영문_SM.indd 51 2017. 8. 25. 오전 11:16