54
2) Defect Inspection
Defect in
Water
Level
Detection
• Water level
surpasses the
preset level.
• Defect in pressure sensor
• Defective PCB
• Defect in water level detection circuit
• Bending or partial blockages of pressure sensor hose
• Defect in pressure sensor
Air leaks in pressure sensor hose
• Defective PCB
• Low frequency from pressure sensor
• Defective PCB
• Impurities in air trip inlet
• Defect in pressure sensor (Defective oscillating condenser)
• Impurities in air trip inlet
• Defective PCB
• Water supply
continues despite
the high water
level.
• Display of "E9"
• The water level is
wrongly measured.
• Defect in water level detection circuit
• Water level runs
below the preset
level.
• The reset level is
immeasurable.
Defects
and Errors
Details Causes
Inspection of Defects
and Errors
Resolution
PCB Error
Mode
Incessant
water
supply
Water continues
to be supplied
although the
inlet valve is
functioning well.
Defect in the bellows of
water level sensor
Check the frequency Exchange the water
level sensor
"E2"
Defect in pressure sensor
hoses
Check the frequency Exchange the hose "E2"
Inspect any openings Exchange the hose "E2"
Blockages in pressure
sensor hoses
Inspect with naked eyes Remove impurities "E2"
Occurrence
of "E9"
The water level
sensor transmits
the frequency of
15KHz or lower
or 30KHz or
higher.
Disconnected connector Inspect the connection of
connector with naked eyes
Re-insert "E9"
Defect in water level
sensor
Check the frequency Exchange the water
level sensor
"E9"
Disconnected wire Inspect the wire connection
-> Inspect the circuit
"E9"
MINI 2.0_COMBO,WASH_영문_SM.indd 54 2017. 8. 25. 오전 11:16