9) "EI" ERROR
Cause : I-SENSOR disconnection / short (pull-down)
Control : After water suppy, Ice drop every 4.8hour.
Termination : When I-SENSOR is normal.
10) "Ft" ERROR
Cause : When Level SW is ERROR
Control : Time control (Skip water supply mode)
Termination : Normal
11) "EF" Error
Cause : When Flow-sensor is ERROR(There is no Pulse during some time.)
When water supply valve is "ON" , Pulse input is below 10 during 1s.
Control : Time control(By Vector time recorded EEPROM.)
(Generally, Water is supplied about 5.5s.)
Termination : Exchang Flow-Sensor.
12) "Eg" Error
Cause : I-Sensor temp(5M after Water supply) dosen t get high.
Control : Normal control
Termination : Normal
13) Dispenser S/W Error
Cause : When it senses 1M continuously.
Control : Stop Dispenser & Crusher function.
Display : Relative ICON BOX is "OFF".
Termination : Normal
14) Malfunction of Ice Drop Motor
Cause : Malfunction of Ice Drop Motor.
[Check the Motor by pushing Test S/W.]
Termination : Exchange Motor
15) "Eu" Error
Cause : Fully TM position is Error
Control : When dropping the Ice, the motor just rotates 90 degree.
Termination : Fully sensor is normal.
16) "EA" Error
Cause : When sensing Ice dropping 3 times with level sensor SW Error.
Control : Pause Ice Maker.
Termination : With level sensor SW is normal,
Reset the Power or Push TEST S/W.
* When all ERROR CODE is normal, the Refrigerator reset.
!
@
#
!
@
#
!
@
#
!
@
!
@
#
!
@
#
!
@
#