OPERATION AND FUCTIONS
Regulation of R-sensor OFF Point
INPUT Control Object
J18, 22 on Main PCB Resistance of R-sensor Mid OFF Point
CONTENTS REMARKS
Regulation of R-sensor OFF point (1.5degree DOWN)
In case refrigeration of refrigerator is weak or insufficient, take the following action.
R-SENSOR
OP 1-2
R26
R70
R71
OPOP 1-1-1
R26 : R-SENSOR standard resistance in normal mode (31.4K )
R70 : In case of weak ref., cut J18 to down the standard resistance by 1.5deg(2K)
R71 : In case of weak ref., cut J22 to down the standard resistance by 1.5deg(2K)
R26 = Mid OFF point
R26 + R70 = Mid OFF point - 1.5 deg
R26 + R70 + R71 = Mid OFF point - 3.0 deg
Summary of Function
CONTENTS REMARKS
How to start function modes
All the modes are started with "LOCK ON" except for "explanation after delivery & installation".
A/S forced defrosting
"FREEZER SET." + "REFRIGERATOR SET." 5
times
Demonstration "REFRIGERATOR SET." + "SLEEP" 5 times
Explanation after delivery &
installation
"REFRIGERATOR SET." for 3 sec. Right after
first power in
ERROR display "REFRIGERATOR SET." + "LOCK" 3 times