Alarm Control Panel Installer Manual
25
Icon
Color
Meaning
Red
Fault status
Green
Bypass
Red
Alarm status of eight Areas
1.16.2 Status
Power LED Indicator ( )
Glows: The system operates with normal power supply.
Slowly flashes: The system does not operate normally due to a lack of power supply, and therefore a
check must be given.
Quickly flashes: The system is in installer programming mode or in the Walk Test Zone mode. If a
lack of power supply occurs when the system is in either of these two modes, the LED indicator also
quickly flashes.
Battery LED Indicator ( )
If power supplies normally, the indicator will not be ON in case of low battery.
Slowly flashes: Battery defects such as low power and powering off quickly.
Off: Battery operates normally.
Fault LED Indicator ( )
Glows: System faults (main power loss, battery low voltage or missing), and you can view the details
on the SYSTEM TROUBLES menu of User Menu.
Slowly flashes: Tampering is happening to the Control Panel, siren, or Keypad.
Off: The system operates normally.
Bypass LED Indicator ( )
Glows: There is at least one bypassed zone.
Off: There is no bypassed zone.
1-8 LED Indicators
There are eight LED indicators located below the LCD display represent the status of the Areas. From left
to right they show the alarm status of Area 1 to Area 8. See Figure 1-12.
Area status LED indicators Figure 1-12