Local alarm Figure 4-66
Configure the parameters. Step 2
Table 4-15 Alarm parameters description
Parameter Description
Alarm Event
Select alarm event. It is Local Alarm by default.
Slot Select the slot of local alarm.
Channel Select the alarm channel.
Channel Name Enter the alarm channel name.
Type
Select external alarm device type. Both NO and NC are supported. Select
the check box to enable the function.
Period
Configure alarm period. Alarm is produced only within the configured
period.
Click Setup to configure alarm period in the following steps:
1. Select week.
2. Configure the time period. A total of 6 periods can be configured.
Click Default Time
, and all periods will be default period,
00:00:00–23:59:59.
Click Current Time, and the period will be the last saved time.
3. Select the day(s) in Apply to zone, so the configured periods will be
applied to the day(s).
4. Click OK.
Alarm Output
Connect alarm output port with alarm devices (such as light and siren
etc.). In case of alarm, the system will send alarm information to alarm
devices.
Click Setup to select slot.
Alarm Output Delay After the alarm is stopped, the alarm output is delayed for some time,
ranging from 10 seconds through 300 seconds.
Anti-dither
The system records only one alarm input event during the configured
period.
Buzzer The system activates a buzzer alarm when an alarm event occurs.
Log The log records alarm information when an alarm event occurs.
Click Save. Step 3