EasyManua.ls Logo

Daikin Altherma 3 GEO Series - To Connect the Thermostat for Passive Cooling

Daikin Altherma 3 GEO Series
252 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 | Electrical installation
Installer reference guide
99
EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12
3 Fix the cable with cable ties to the cable tie mountings.
8.2.12 To connect the thermostat for passive cooling
INFORMATION
Restriction: Passive cooling is only possible for:
Heating only models
Brine temperatures between 0 and 20°C
Wires: 2×0.75mm²
1 Open the following (see "6.2.2To open the indoor unit"[455]):
1 Top panel
1
3
2
2 User interface panel
3 Installer switch box cover
2 Connect the thermostat cable to the appropriate terminals as shown in the
illustration below.
X2M
34a
30
R1T
-t°
3 Fix the cable with cable ties to the cable tie mountings.