7 | Installation
Installer reference guide
101
ERGA04~08DAV3(A) + EHBH/X04+08DA*V7
Daikin Altherma 3 R W
4P618958-1 – 2020.03
7.9.11 To connect the electricity meters
INFORMATION
In case of an electricity meter with transistor output, check the polarity. The positive
polarity MUST be connected to X5M/6 and X5M/4; the negative polarity to X5M/5
and X5M/3.
1 Connect the electricity meters cable to the appropriate terminals as shown in
the illustration below.
X5M
S2S S3S
3
4
56
2 Fix the cable with cable ties to the cable tie mountings.
7.9.12 To connect the domestic hot water pump
1 Connect the domestic hot water pump cable to the appropriate terminals as
shown in the illustration below.
X2M
X1M
1~
M
M2P
1 2
2 Fix the cable with cable ties to the cable tie mountings.
7.9.13 To connect the alarm output
1 Connect the alarm output cable to the appropriate terminals as shown in the
illustration below.