7 | Unit installation
Installer reference guide
52
EVLQ05+08CA + EHYHBH05A + EHYHBH/X08A + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1G – 2022.09
▪ Make sure the installation site withstands the total weight and vibration of the
installation.
Module Weight
Hybrid module 30kg
Gas module 36kg
Indoor part (Hybrid module + gas
module)
Total weight: 66kg
Do NOT install the unit in places such as:
▪ In places where a mineral oil mist, spray or vapour may be present in the
atmosphere. Plastic parts may deteriorate and fall off or cause water leakage.
▪ Sound sensitive areas (e.g. near a bedroom), so that the operation noise will
cause no trouble.
▪ In places with high humidity (max. RH=85%), for example a bathroom.
▪ In places where frost is possible. Ambient temperature around the indoor unit
must be >5°C.
7.2 Opening and closing the units
7.2.1 About opening the units
At certain times, you have to open the unit. Example:
▪ When connecting the refrigerant piping
▪ When connecting the electrical wiring
▪ When maintaining or servicing the unit
DANGER: RISK OF ELECTROCUTION
Do NOT leave the unit unattended when the service cover is removed.
7.2.2 To open the outdoor unit
DANGER: RISK OF ELECTROCUTION