17 | Technical data
Installer reference guide
247
EVLQ05+08CA + EHYHBH05A + EHYHBH/X08A + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1G – 2022.09
EHYKOMB33AA*
Manometer Digital
Drain/fill valve No (optional in connection set)
Shut‑off valves No (optional in connection set)
Air purge valve Yes (manual)
Domestic hot water circuit (not applicable for Switzerland)
Domestic hot water piping connections Ø15mm
Piping material Cu
Gas/flue gas
Gas connection Ø15mm
Flue gas/combustion air connection Concentric connection
Ø60/100mm
Electrical
Power supply voltage 230V
Power supply phase 1~
Power supply frequency 50Hz
IP class IPX4D
Absorbed power: full load 80W
Absorbed power: standby 2W
Auxiliary electricity consumption at full load
(elmax)
0.040kW
Auxiliary electricity consumption at part load
(elmin)
0.015kW
Auxiliary electricity consumption in standby
mode (P
SB
)
0.002kW
Radio module
Power supply 230VAC mains powered
Frequency range 868.3MHz
Effective Radiated Power (ERP) 12.1dBm
17.7.2 Energy-related products specifications
Technical product file in accordance to CELEX-32013R0811
Supplier Daikin Europe N.V.,
Zandvoordestraat 300,
BE-8400 Oostende, Belgium
Type designation EHYKOMB33AA*
Seasonal space heating energy efficiency class — — A
Heat rated output Prated kW 27
Annual energy consumption Q
HE
GJ 53
Seasonal space heating energy efficiency η
S
% 93