EasyManua.ls Logo

Daikin EHVX08S23DA6V User Manual

Daikin EHVX08S23DA6V
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installer reference guide
Daikin Altherma – Low temperature split
English
Installer reference guide
Daikin Altherma – Low temperature split
ERGA04DAV3(A)
ERGA06DAV3(A)
ERGA08DAV3(A)
EHVH04S18DA6V(G)
EHVH04S23DA6V(G)
EHVH08S18DA6V(G)
EHVH08S23DA6V(G)
EHVH08S18DA9W(G)
EHVH08S23DA9W(G)
EHVX04S18DA3V(G)
EHVX04S18DA6V(G)
EHVX04S23DA3V(G)
EHVX04S23DA6V(G)
EHVX08S18DA6V(G)
EHVX08S23DA6V(G)
EHVX08S18DA9W(G)
EHVX08S23DA9W(G)
Final English - Tanslations in progress

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin EHVX08S23DA6V and is the answer not in the manual?

Daikin EHVX08S23DA6V Specifications

General IconGeneral
BrandDaikin
ModelEHVX08S23DA6V
CategoryHeat Pump
LanguageEnglish

Summary

General Safety Precautions

For the Installer

General guidance and responsibilities for the installer.

Refrigerant Handling

Precautions and requirements for handling refrigerant during installation.

Electrical Safety Precautions

Critical safety measures for electrical wiring and connections.

Application Guidelines

Space Heating and Cooling Setup

Guides on setting up the system for space heating and cooling.

Single Room System Setup

Details setup for single-room heating/cooling with wired or wireless thermostats.

Multi-Room, Single LWT Zone Setup

Describes setup for multi-room systems with one leaving water temperature zone.

Multi-Room, Two LWT Zones Setup

Details setup for multi-room systems with two leaving water temperature zones.

Domestic Hot Water Tank Setup

Covers system layout, volume selection, and desired temperature for DHW tanks.

External Temperature Sensor Setup

Guides on connecting and configuring external temperature sensors.

Preparation

Installation Site Preparation

Guidelines for preparing the installation site, considering environmental factors.

Refrigerant Piping Preparation

Covers requirements for refrigerant piping material, diameter, and insulation.

Refrigerant Piping Requirements

Specifies piping material, diameter, temper grade, and thickness.

Water Piping Preparation

Covers requirements for preparing the water piping system.

Preferential kWh Rate Power Supply

Information on connecting to preferential kWh rate power supply systems.

Installation

Mounting the Outdoor Unit

Covers the process of mounting the outdoor unit, including structure and precautions.

Installing the Outdoor Unit

Steps for positioning and fixing the outdoor unit in place.

Providing Drainage

Instructions for ensuring proper drainage of condensation water from the outdoor unit.

Mounting the Indoor Unit

Covers the process of mounting the indoor unit.

Installing the Indoor Unit

Steps for positioning, leveling, and installing the indoor unit.

Connecting Refrigerant Piping

Details the process of connecting the refrigerant piping between units.

Refrigerant Piping Connection Precautions

Critical precautions for connecting refrigerant piping safely and correctly.

Refrigerant Piping Connection Guidelines

Best practices and guidelines for connecting the refrigerant piping.

Using Stop Valves and Service Ports

How to properly use and handle stop valves and service ports.

Connecting Outdoor Unit Refrigerant Piping

Instructions for connecting refrigerant piping to the outdoor unit's stop valves.

Connecting Indoor Unit Refrigerant Piping

Instructions for connecting refrigerant piping to the indoor unit's connections.

Checking the Refrigerant Piping

Procedures for checking the refrigerant piping for leaks and moisture.

Refrigerant Piping Checking Precautions

Critical precautions for checking refrigerant piping, including vacuum pump usage.

Leak Checking Procedure

Steps for performing a leak test on the refrigerant piping using a bubble solution.

Vacuum Drying Procedure

Detailed steps for vacuum drying the refrigerant piping to remove moisture.

Charging Refrigerant

Covers the process of charging refrigerant into the system.

Refrigerant Charging Precautions

Critical precautions to follow when charging refrigerant into the system.

Determining Additional Refrigerant Amount

Guidance on calculating the additional refrigerant needed based on piping length.

Charging Additional Refrigerant

Step-by-step process for charging additional refrigerant into the system.

Connecting Water Piping

Guides on connecting the water piping to the indoor unit and system.

Water Piping Connection Precautions

Critical precautions for connecting water piping safely and correctly.

Connecting the Water Piping

Steps for connecting space heating and DHW water piping to the indoor unit.

Connecting Drain Hose to Drain

Steps for connecting the drain hose from the unit to an appropriate drain.

Filling the Water Circuit

Procedure for filling the water circuit with water, complying with legislation.

Filling the Domestic Hot Water Tank

Steps for filling the domestic hot water tank and purging air.

Connecting Electrical Wiring

Comprehensive guide to connecting all electrical wiring for the system.

Electrical Wiring Connection Precautions

Critical safety precautions for connecting electrical wiring.

Electrical Wiring Connection Guidelines

Best practices for installing wires and ensuring secure connections.

Connecting Outdoor Unit Electrical Wiring

Steps for connecting electrical wiring to the outdoor unit.

Connecting Indoor Unit Electrical Wiring

Steps for connecting electrical wiring to the indoor unit.

Connecting Main Power Supply

Guides on connecting the main power supply to the unit.

Backup Heater Power Supply Connection

Instructions for connecting the power supply for the backup heater.

Connecting Safety Thermostat

How to connect wiring for the safety thermostat.

Configuration

Configuration Wizard

Guides the user through initial system setup using a wizard.

Settings Menu

Covers settings for malfunctions and room temperature control.

Room Settings

Covers settings for room temperature control, schedules, and frost protection.

Main Zone Settings

Details configuration for the main heating/cooling zone, including schedules and curves.

Control Mode Settings

Configuring the unit's control mode, such as LWT, external, or room thermostat.

Additional Zone Settings

Configuration options for the additional heating/cooling zone.

Space Heating/Cooling Operation Modes

Configuring how the unit operates for space heating and cooling.

Pump Operation Mode Settings

Configuring the pump operation mode based on system status and requests.

Tank Settings

Covers all settings related to the domestic hot water tank.

Disinfection Function Configuration

Configuring the disinfection function for the domestic hot water tank.

Installer Settings

Covers configuration wizard, DHW, backup heater, and balancing settings.

Domestic Hot Water Settings

Configuring DHW preparation, DHW pump, and schedule.

Backup Heater Configuration

Setting up the backup heater type, voltage, and configuration.

Power Consumption Control Setup

Configuring power consumption control and limitation levels.

Energy Metering Setup

Configuring settings for external electricity meters.

Bivalent Operation Settings

Configuring bivalent operation with auxiliary boilers.

Bivalent ON Temperature and Hysteresis

Setting bivalent ON temperature and hysteresis for auxiliary boiler control.

Operation Settings

Enabling or disabling specific unit functionalities like room, heating/cooling, and tank.

Menu Structure: Overview Installer Settings

Commissioning

Commissioning Precautions

Important precautions to follow before and during commissioning.

Checklist Before Commissioning

A checklist of essential checks to perform before starting the commissioning process.

Commissioning Checklist

A checklist of items to verify during the commissioning process.

Minimum Flow Rate Check

Verifying the minimum flow rate is guaranteed for defrost/backup heater operations.

Air Purge Procedures

Steps for performing manual and automatic air purging of the water circuit.

Operation Test Run

Performing a test run to verify system operation in heating/cooling modes.

Actuator Test Run

Testing the functionality of individual actuators like pumps and valves.

Underfloor Heating Screed Dryout

Procedure for drying out the screed of an underfloor heating system.

Maintenance and Service

Maintenance Safety Precautions

Safety measures to be followed during maintenance and service work.

Outdoor Unit Yearly Maintenance Checklist

Checklist for routine yearly maintenance tasks on the outdoor unit.

Indoor Unit Yearly Maintenance Checklist

Checklist for routine yearly maintenance tasks on the indoor unit.

Cleaning Water Filter (In Case of Trouble)

Instructions for cleaning the water filter when encountering issues.

Troubleshooting

Troubleshooting Precautions

Safety precautions and general advice before troubleshooting.

Solving Problems by Symptom

Guides on diagnosing and resolving issues based on observed symptoms.

Symptom: Unit Not Heating or Cooling Correctly

Troubleshooting steps for incorrect heating or cooling performance.

Symptom: Compressor Not Starting

Diagnosing why the compressor fails to start for heating or DHW.

Symptom: Pump Noise (Cavitation)

Identifying and resolving causes of pump noise, such as air or low pressure.

Solving Problems by Error Code

Guides on understanding and resolving system issues using error codes.

Technical Data

Field Settings Table

Related product manuals