Air to water heat pump units with scroll compressors split
version
EWYT~CZ(I/O)
Original Instructions
Installation and Maintenance Manual
D-EIMHP01505-22_00EN

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin EWYT040CZI-A1 and is the answer not in the manual?

Daikin EWYT040CZI-A1 Specifications

General IconGeneral
ModelEWYT040CZI-A1
CategoryHeat Pump
Cooling Capacity4.0 kW
Coefficient of Performance (COP)4.0
RefrigerantR-32
Operating Temperature Range (Heating)-15°C to 24°C

Summary

Introduction, Unit Description, and Safety

1.1. Precautions Against Residual Risks

Essential safety measures to prevent injuries and hazards during installation and operation.

1.5. Installation Site Requirements

Outlines crucial requirements for selecting a suitable installation location for the indoor unit.

1.5.1. Installation Room Area Requirements

Specifies requirements for the installation room area, considering toxicity and flammability.

1.5.2. Countermeasures

Details safety countermeasures like ventilation and alarms based on refrigerant charge and location.

Unit Receipt, Storage, and Mechanical Installation

4. Mechanical Installation Procedures

Comprehensive steps and precautions for installing the unit's mechanical components.

4.1. Installation Safety Precautions

Safety precautions for personnel performing mechanical installation tasks.

4.2. Unit Handling and Lifting

Procedures and precautions for safely handling and lifting the unit components.

4.3. Outdoor Unit Positioning and Assembly

Guidelines for positioning and assembling the outdoor unit on a suitable foundation.

4.7. Refrigerant Piping Preparation

Essential precautions for preparing refrigerant piping to ensure system cleanliness, dryness, and tightness.

Electrical Installation

Refrigerant Piping Connection and Charging

6.3. Connecting Piping to Outdoor Unit

Step-by-step guide for connecting the refrigerant piping to the outdoor unit.

6.4. Connecting Piping to Indoor Unit

Step-by-step guide for connecting the refrigerant piping to the indoor unit.

6.5. Refrigerant Piping Checks

Workflow for checking refrigerant piping for leaks, vacuum drying, and insulation.

6.5.1. Pressure Leak Test

Procedure for performing a pressure leak test on the refrigerant piping system using nitrogen.

6.5.2. Vacuum Drying Procedure

Instructions for performing vacuum drying to remove moisture and air from the refrigerant circuit.

6.6. Refrigerant Charging Procedures

Procedures and precautions for charging the system with refrigerant after vacuum drying.

6.6.1. Precautions During Charging

Safety precautions and procedures to follow when charging the system with refrigerant.

6.6.4. Post-Charging Checks

Final checks after refrigerant charging, including opening valves and recording charge amount.

Operator Responsibilities and Maintenance

8. Maintenance Procedures

Guidance on maintaining the unit for optimal performance, longevity, and safety.

Commissioning and Final Information

11. Unit Commissioning Checklist

Checklist and guidelines for the commissioning process, to be performed by authorized personnel.

Related product manuals