8
Care
Cleaning the air lter
Clean the air lter when the air lter cleaning time
indicator lamp on the decoration panel lights up or
when “Time to clean lter” displays on the wired
remote controller.
•If the unit is installed in a room where the impurity
contentoftheairishigh,cleantheltermorefrequently.
•
Ifthelterhasbecomedifculttoclean,replacetheairlter.
(Additionalairltersoldseparately.)
1. Open the suction grille.
•Push the 2 catches away from you and slowly open
the suction grille. (To close, perform the steps in
reverse.)
Type A Type B
Catch
Catch
2. Remove the air lter.
•Pulltheknobsoftheairlterdownwardto
disconnectthehooks,andremovetheairlter.
Hook
Knob
3. Clean the air lter with a
vacuum cleaner or wash it
with water.
If the dust does not come off easily
•Washtheairlterusingasoftbrushandaneutral
detergent, then let it dry in the shade.
4. Reattach the air lter.
4-1 Hookonesideoftheairlterontotheprotrusionson
the suction grille.
4-2 Pushtheothersideoftheairlterintoplace.
Protrusion
5. Close the suction grille.
•Refer to STEP 1.
6. After turning on the power,
reset the lter sign in
accordance with the
instructions in the
operation manual for the
wired remote controller or
wireless remote controller.
•Theairltercleaningtimeindicatorlamponthe
decorationpanelturnsoffor“Timetocleanlter”
disappears from the display on the wired remote
controller.
01_EN_3P674698-1.indd 8 3/15/2022 4:35:53 PM