Si04-958 Removal of PCBs
Removal Procedure 15
11
Remove the signal
receiver PCB.
12
Disconnect the
connector.
[S48]: control PCB
2. Remove the
INTELLIGENT EYE
sensor PCB.
1
Unfasten the 2 hooks
on the right and then
the 2 hooks on the left.
Remove the
INTELLIGENT EYE
sensor ASSY.
Step
Procedure Points
(R9521)
(R9522)
[S48]
(R9523)
Hook
Hook
INTELLIGENT EYE
sensor ASSY
(R9524)