2 | Components
Service manual
60
FTXA20~50A(W)(S)(T) + FTXA20~50B(B)(S)(T) + RXA42+50A +
RXA20~35A(9) + RXA42+50B
Split Stylish R32
ESIE18-03D – 2021.05
Is the problem solved? Action
No Return to the troubleshooting of the
specific error and continue with the
next procedure.
2.3.2 Repair procedures
To remove the expansion valve coil
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see "2.14Plate work"[4120].
1 If needed, remove any parts or insulation to create more space for the
removal.
2 Remove the cap (if appliccable) from the expansion valve coil.
a Expansion valve coil cap
3 Pull up the expansion valve coil to remove it from the expansion valve body.
INFORMATION
It may be needed to turn the expansion valve coil 1/8 turn counter clockwise to
unlock it. Make sure to note the correct orientation (position) of the expansion valve
coil before removal.
a Expansion valve coil