Loading...
9 | Finishing the indoor unit installation
Installer reference guide
45
CTXA15+FTXA25~50(A)(B)2V1B(W)(S)(T)(B)
Daikin room air conditioner
4P518023-3K – 2022.05
9.4.2 To close the service cover
1 Place the service cover to its original place on the unit.
2 Install 1 screw back on the service cover.
NOTICE
When closing the service cover, make sure that the tightening torque does NOT
exceed 1.4(±0.2)N•m.
9.4.3 To re-install the front panel
1 Attach the front panel.
2 Align the shaft on right side with the shaft slot and insert it all the way in.
3 Push lightly the front panel to the right side, align the shaft on the left side
with slot and insert it all the way in.
4 Close the locks on both sides.
9.4.4 To close the front panel
1 Lift the front panel slightly and remove the support from the fixing tab.
a
b
c
a Backside of the front panel
b Fixing tab
c Support
2 Close the front panel.
3 Gently press the front panel down until it clicks.
9.4.5 To install the screw covers
1 Open the front panel and turn the flap up.
2 Install both screw covers (1 on each side).
1
2
3 Return flap to its original position and close the front panel.

Table of Contents