6.3.3 To remove the pipe port cover
INFORMATION
To connect the piping on right-side, right-bottom, left-side or left-bottom, the pipe
port cover MUST be removed.
1 Cut off the pipe port cover from inside the front grille using a coping saw.
2 Remove any burrs along the cut section using a half round needle file.
NOTICE
Do NOT use nippers to remove the pipe port cover, as this would damage the front
grille.
6.4 Connecting the drain piping
In this chapter
6.4.1 General guidelines.................................................................................................................................................. 29
6.4.2 To connect the piping on right side, right-back, or right-bottom......................................................................... 30
6.4.3 To connect the piping on left side, left-back, or left-bottom................................................................................ 31
6.4.4 To check for water leaks ........................................................................................................................................ 32
6.4.1 General guidelines
Pipe length. Keep drain piping as short as possible.
Pipe size. If drain hose extension or embedded drain piping is required, use
appropriate parts that match the hose front end.
Ø16
Ø18
NOTICE
Install the drain hose with a downward slope.
Traps are NOT permitted.
Do NOT put the end of the hose in water.