5 Installation
Installation manual
5
CTXA15+FTXA25~50(A)(B)2V1B(W)(S)(T)(B)
Daikin room air conditioner
3P482320-7P – 2019.10
1 Open the front panel. Refer to "5.1.1 To open the front
panel"[44].
2 Remove the service cover. Refer to "5.1.4To open the service
cover"[44].
3 Remove the wire harness from the wire clamp and the
connector.
4 Remove the flap by pushing it to the left side and towards you.
5 Remove the 2 screw covers using a long flat plate such as a
ruler wrapped in a cloth and remove 2 screws.
a Connector
b Wire clamp
c Screw cover
d Long flat plate wrapped in a cloth
6 Push the front grille up and then towards the mounting plate to
remove the front grille from the 3 hooks.
a Hook
Prerequisite: If working space is limited.
7 Insert a flat screwdriver next to the hooks.
8 Pull the front grille up using the flat screwdriver and push
towards the mounting plate.
a Hook
b Flat screwdriver
5.1.6 To re-install the front grille
1 Install the front grille and firmly engage the 3 upper hooks.
2 Tighten the 2 screws and put the 2 screw covers back.
3 Re-install the flap.
4 Insert the wire harness back into the connector and secure it
with the wire clamp.
5 Close the front panel. Refer to "5.1.2 To close the front
panel"[44].
5.1.7 To remove the electrical wiring box cover
1 Remove the front grille.
2 Remove 1 screw from the electrical wiring box.
3 Open the electrical wiring box cover by pulling it to the front.
4 Remove the electrical wiring box cover from the 2 rear hooks.
a Screw
b Electrical wiring box
c Rear hook
5 To re-install the cover, first attach the electrical wiring box to the
hooks, close the electrical wiring box, and re-install the screw.
5.2 Installing the indoor unit
5.2.1 To install the mounting plate
1 Install the mounting plate temporarily.
2 Level the mounting plate.
3 Mark the centres of the drilling points on the wall using a tape
measure. Position the end of tape measure at symbol " ".
4 Finish the installation by securing the mounting plate on the wall
using M4×25L screws (field supply).
INFORMATION
The removed pipe port cover can be kept in the mounting
plate pocket.