74
6.2 Electronic Expansion Valve (EXV) checking procedures
a. Check if the EXV connector is correctly connected to PCB.
b. Turn power off and on again, and check if EXV generates a latching sound.
c. If the EXV does not generate a latching sound in above step b., disconnect connector and check
continuity using a multimeter.
d. Check the continuity between pins [1-6, 3-6, 2-5, 4-5 (between pins 1-6, 2-6, 3-6, 4-6 for harness 5P
models)]. If there is no continuity between the pins, EXV coil is faulty.
e. Ifthecontinuityisconrmedinstepd.,outdoorPCBisfaulty.
Harness 6P
6P Connector
1
kcehC02S
(R106366)
1 - 6
3 - 6
2 - 5
4 - 5
2 3 4 5 6
Harness 5P
6P Connector
(5)
1
kcehC02S
(R106366)
1 - 6
3 - 6
2 - 6
4 - 6
2 3 4 5 6
6.3 Four way valve performance checking procedures
6.3.1 Class 25/35
Turn power off and then
on again.
Disconnect four way valve coil
from connector and check the
continuity.
Start heating operation.
Replace four way valve.
S80 voltage at
180-280V with
compressor on?
Four way
valve coil resistance at
Yes
Yes
Replace outdoor PCB.
Replace four way valve coil.
No
*Refer Figure 1 below.
No
(Fig. 1)
Voltage at S80
DC180-280V
DC12-15V
Compressor
ON Time
*Four way valve coil
Not Energized
Heating: Energized