EasyManua.ls Logo

Daikin FTXF09AXVJU User Manual

Daikin FTXF09AXVJU
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSTALLATION MANUAL
R32 SPLIT SERIES
Installation Manual
R32 Split Series
English
Manual de instalación
Serie Split R32
Español
Manuel d’installation
Série split R32
Français
DAIKIN ROOM AIR CONDITIONER
3P601788-4 K
MODELS
FTXF09AXVJU
FTXF12AXVJU
FTXF18AXVJU
FTXF24AXVJU
RXF09AXVJU
RXF12AXVJU
RXF18AXVJU
RXF24AXVJU
FTKF09AXVJU
FTKF12AXVJU
FTKF18AXVJU
FTKF24AXVJU
RKF09AXVJU
RKF12AXVJU
RKF18AXVJU
RKF24AXVJU
FTXC09AXVJU
FTXC12AXVJU
FTXC18AXVJU
FTXC24AXVJU
RXC09AXVJU
RXC12AXVJU
RXC18AXVJU
RXC24AXVJU
01_IM-FTX&FTK-DAIKIN_3P601788-4 K-EN.indb 101_IM-FTX&FTK-DAIKIN_3P601788-4 K-EN.indb 1 17/10/2023 4:34:02 PM17/10/2023 4:34:02 PM
Question and Answer IconNeed help?

Do you have a question about the Daikin FTXF09AXVJU and is the answer not in the manual?

Daikin FTXF09AXVJU Specifications

General IconGeneral
BrandDaikin
ModelFTXF09AXVJU
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Precautions

Warning and Caution Notices

Explains the meaning of WARNING and CAUTION notices for safe installation.

General Safety Marks

Details the meaning of safety marks like 'Be sure to follow' and 'Ground connection'.

Installation and Electrical Warnings

Covers warnings for qualified personnel, power, wiring, and refrigerant handling.

Handling and Environmental Cautions

Cautions for installation, unit handling, environmental factors, and refrigerant safety.

Refrigerant Charge Labeling

Guidance on filling and affixing the refrigerant charge label.

Included Accessories

Accessory List and Details

Lists all accessories provided with the air conditioner unit.

Installation Site Selection

Indoor Unit Placement Guidelines

Guidelines for selecting an appropriate location for the indoor unit.

Outdoor Unit Placement Guidelines

Recommendations for outdoor unit placement considering environmental factors.

Remote Controller Signal Reception

Tips for indoor unit installation to ensure good remote controller signal reception.

Indoor/Outdoor Unit Installation Drawings

Indoor Unit Mounting and Clearances

Diagrams and dimensions for indoor unit installation and required clearances.

Outdoor Unit Piping Specifications

Details on pipe length, height, and refrigerant charge requirements.

Indoor Unit Installation

Mounting Plate Installation Procedure

Instructions for securely installing the indoor unit's mounting plate.

Indoor Unit Mounting Dimensions

Detailed dimensions for mounting plate placement for Class 09/12 and 18/24 units.

Drilling Wall Hole and Pipe Installation

Wall Hole and Pipe Installation Procedure

Steps for drilling the wall hole and installing wall pipes and covers.

Indoor Unit Mounting

Right-Side Piping Installation

Steps for installing the indoor unit with right-side piping configurations.

Left-Side Piping Installation

Steps for installing the indoor unit with left-side piping configurations.

Drain Hose and Plug Management

Instructions for attaching and managing the drain hose and drain plug.

Wall Embedded Piping Installation

Procedure for installing wall embedded piping for the indoor unit.

Indoor Unit Mounting Method

Steps on how to attach and remove the indoor unit from the mounting plate.

Drain Piping Installation

Drain Hose Connection and Extension

Guidance on connecting the drain hose, ensuring proper inclination and extension.

Water Drainage Best Practices

Illustrates correct and incorrect water drainage methods.

General Wiring Guidelines

Wiring Diagram and Recommendations

Shows indoor/outdoor unit wiring connections and recommends wire types.

Wiring Cautions and Best Practices

Highlights cautions for wiring, terminal connections, and wire management.

Outdoor Unit Installation

Outdoor Unit Installation Patterns

Provides installation guidelines based on wall configurations and unit classes.

Outdoor Unit Drain Work

Outdoor Unit Drainage Procedure

Instructions for drain socket usage and considerations for cold areas.

Pipe Flaring

Pipe Flaring Procedure

Steps for cutting, burr removal, and flaring pipe ends for refrigerant connections.

Flaring Quality Check

Checks to ensure proper flaring for refrigerant gas leakage prevention.

Refrigerant Piping Installation

Flare Nut and Oil Application

Cautions on using flare nuts and applying refrigeration oil for joints.

Pipe Bending and Material Selection

Guidelines for bending pipes and selecting copper/insulation materials.

Insulation and Piping Dimensions

Details on insulating gas/liquid piping and required insulation sizes.

Safety Precautions for Refrigerant Work

Emphasizes safety during refrigerant handling, including ventilation and ignition sources.

Refrigerant Leak Detection and Checks

Covers leak detection methods, installation checks, and safety precautions.

Refrigerant Recovery and Procedures

Details on refrigerant removal, evacuation, charging, and decommissioning.

Purging Air and Leak Check

Purging and Leak Test Warnings

Warnings against mixing substances and emphasizes safe refrigerant recovery.

Pressure Test and Evacuation Procedure

Steps for pressure testing, evacuation, and checking for gas leaks.

Pump Down Operation

Pump Down Procedure and Safety

Detailed steps for pump down operation and critical safety warnings.

Wiring Connections and Safety

Wiring Safety and Connection

Safety precautions and instructions for connecting inter-unit wires.

Circuit Breaker Ratings

Specifies circuit breaker ratings for different unit classes.

Electrical Wiring Connection Details

Conduit Mounting for Class 09/12

Method for mounting conduit and protection plates for Class 09/12 units.

Conduit Mounting for Class 18/24

Method for mounting conduit and service lids for Class 18/24 units.

Facility Setting for Low Temperature

Facility Setting Functionality

Explains the facility setting for extended operation range in low temperatures.

Jumper Location for Facility Setting

Shows the location of jumpers J6 and J4 for facility setting on the PCB.

Commissioning Checks

Pre-Commissioning Installation Checklist

Ensures all installation steps are completed correctly before system operation.

Commissioning Procedures

Checks to perform during the commissioning phase, including air purge and test run.

System Indication Lights

IR Signal Receiver Confirmation

Describes how the unit confirms acceptance of remote control signals.

LED Indicator Lights Explanation

Details normal operation and fault condition LED indicator lights for heatpump units.

Operating Range Charts

Cooling Only Model Operating Range

Graphs showing operating temperature ranges for cooling-only models.

Heatpump Model Operating Range

Graphs showing operating temperature ranges for heatpump models (cooling/heating).

Maintenance and Service Guide

Maintenance Recommendations

Recommends maintenance by authorized personnel and yearly checks.

Safety Precautions for Maintenance

Critical safety warnings for maintenance, including electrical hazards.

Outdoor Unit Maintenance Checklist

Specific checks for the outdoor unit's heat exchanger and overall condition.

Unit Disposal Instructions

Proper Unit Disposal Guidelines

Instructions on how to properly dispose of the unit and its components.