7 | Technical data
Service manual
96
RXJ20~50A + FTXJ-A(W)(S)(B)
Split Emura 3 R32
ESIE22-04 – 2022.04
Overview of field settings for indoor units
The overview lists all possible settings for the indoor units. Bold content is default setting.
Mode Description function Setting Description selection
3 Suspend (Reduce the standby power consumption) 0 Suspend ON
1 Suspend OFF
5 Preheating (pre‑heating of compressor by motor) 0 OFF
1 ON
6 Cooling room temperature correction 0 Low 2
1 Low 1
2 Standard
3 High 1
4 High 2
7 Heating room temperature correction 0 Low 2
1 Low 1
2 Standard
3 High 1
4 High 2
10 Auto restart after power resume (after shutdown) 0 OFF
1 ON
14 Wind direction towards people during heating
(Intelligent Eye)
0 Avoid Human
1 Towards Human (heating only)
15 Ceiling airflow setting for Cooling 0 OFF
1 ON
16 Reduce vertical flow (in case of furniture or
obstacle)
0 Auto
1 Fixed
1E Room temperature sensor selection 0 Unit
1 Wired remote controller
2 WLAN
21 Cooling or Heating mode lock 0 OFF (heating & cooling)
1 Cooling only
2 Heating only
draft–22/04/2022 08:50