6 | Unit installation
Installer reference guide
27
FTXJ-A(W)(S)(B)
Daikin room air conditioner
4P518023-12K – 2022.05
9 Pull the front grille up using the flat screwdriver and pull towards the front
side.
a Slot
b Half-moon shaped dent
6.2.5 To remove the electrical wiring box cover
Prerequisite: Remove the front grille.
1 Remove 1 screw from the electrical wiring box.
2 Open the electrical wiring box cover by pulling it to the front.
3 Remove the electrical wiring box cover from the 2 rear hooks.
a Screw
b Electrical wiring box
c Rear hook
4 To re-install the cover, first attach the electrical wiring box to the hooks, close
the electrical wiring box, and re-install the screw.
NOTICE
When closing the electrical wiring box cover, make sure that the tightening torque
does NOT exceed 2.0(±0.2)N•m.
6.3 Mounting the indoor unit
In this chapter
6.3.1 To install the mounting plate................................................................................................................................. 27
6.3.2 To drill a wall hole .................................................................................................................................................. 28
6.3.3 To remove the pipe port cover.............................................................................................................................. 29
6.3.1 To install the mounting plate
1 Install the mounting plate temporarily.
2 Level the mounting plate.
3 Mark the centres of the drilling points on the wall using a tape measure.
Position the end of tape measure at symbol " ".