EasyManua.ls Logo

Daikin FTXJ35A2V1BW - To Check for Water Leaks

Daikin FTXJ35A2V1BW
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 | Unit installation
Installer reference guide
32
FTXJ-A(W)(S)(B)
Daikin room air conditioner
4P518023-12K – 2022.05
3 Insert the drain hose on the left side and do not forget to tighten it with the
fixing screw; otherwise water leakage may occur.
a
b
a
b
a Insulation fixing screw
b Drain hose
4 Attach the drain hose to the refrigerant piping bottom side using adhesive
vinyl tape.
A
B
C
b
a
A Left-side piping
B Left-back piping
C Left-bottom piping
a Remove the pipe port cover here for left-side piping
b Remove the pipe port cover here for left-bottom piping
6.4.4 To check for water leaks
1 Remove the air filters.
2 Gradually pour approximately 1 l of water in the drain pan, and check for
water leaks.