Daikin FTXJ35A2V1BW - Specifications of Standard Wiring Components; To Connect the Electrical Wiring to the Indoor Unit

Daikin FTXJ35A2V1BW
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 | Electrical installation
Installer reference guide
40
FTXJ-A(W)(S)(B)
Daikin room air conditioner
4P518023-12K – 2022.05
Wire type Installation method
Single-core wire
c b
c
aa
A
AA´
a Curled single-core wire
b Screw
c Flat washer
Stranded conductor wire
with round crimp-style
terminal
c b ba c
a
B
B
a Terminal
b Screw
c Flat washer
Allowed
NOT allowed
The earth wire between the wire retainer and the terminal must be longer than
the other wires.
1-3
8.1.3 Specifications of standard wiring components
Component
Interconnection cable (indoor↔outdoor) 4-core cable 1.5mm²~2.5mm²
andapplicable for 220~240V
H05RN-F (60245 IEC 57)
8.2 To connect the electrical wiring to the indoor unit
Electrical work should be carried out in accordance with the installation manual
and the national electrical wiring rules or code of practice.
1 Set the indoor unit on the mounting plate hooks. Use the " " marks as a
guide.
a
b
c
d
a Mounting plate (accessory)
b Piece of packing material