EasyManua.ls Logo

Daikin FTXN09KEVJU - Check; Thermistor Resistance Check

Daikin FTXN09KEVJU
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Check SiUS041111
116 Service Diagnosis
5. Check
5.1 Thermistor Resistance Check
Check No.01 Disconnect the connectors of the thermistors from the PCB, and measure the resistance of each
thermistor using tester.
The relationship between normal temperature and resistance is shown in the table and the graph
below.
For the models in which the thermistor is directly mounted on the PCB, disconnect the
connector for the PCB and measure.
Thermistor temperature (°C / °F)
Resistance (k)
Room temperature thermistor for
09/12 class model
Other thermistors
–20 / –4 73.4 211.0
–15 / 5 57.0 150.0
–10 / 14 44.7 116.5
–5 / 23 35.3 88.0
0 / 32 28.2 67.2
5 / 41 22.6 51.9
10 / 50 18.3 40.0
15 / 59 14.8 31.8
20 / 68 12.1 25.0
25 / 77 10.0 20.0
30 / 86 8.2 16.0
35 / 95 6.9 13.0
40 / 104 5.8 10.6
45 / 113 4.9 8.7
50 / 122 4.1 7.2
(R25°C (77°F) = 10 k,
B = 3435 K)
(R25°C (77°F) = 20 k,
B = 3950 K)
(11906)
Other thermistorsRoom temperature thermistor
for 09/12 class model
5325986113
(˚C)
(˚F)
5 32 59 86 113
(˚F)
(˚C)
50
25
0
–15
0
15 30
45
(kΩ)
(kΩ)
Tester
Resistance range
(R11906)
RTH1
Tester
(R3460)