Dimensions EDUS041111_a
12 Room Air Conditioners K-Series
4. Dimensions
4.1 Indoor Unit
FTXN09/12KEVJU
FTXN15/18/24KVJU
AIR FLOW (INDOOR)
THE MARK (®) SHOWS PIPING DIRECTION
REAR
30-5/16(770mm)
RIGHT
LEFT
1-3/16(30mm)MIN.
INCLUDING
MOUNTING PLATE
(SPACE FOR
PERFORMANCE)
7-7/8(200mm)
1-15/16(50mm)MIN.
1-15/16(50mm)MIN.
7-51/64(198mm)
(SPACE FOR
(SPACE FOR
FRONT PANEL FIXING SCREWS
REQUIRED SPACE
MAINTENANCE)
MAINTENANCE)
(INSIDE)
GENERAL RATING
NAME PLATE
SIGNAL RECEIVER
TERMINAL BLOCK
OPERATION LAMP
WITH GROUND
TIMER LAMP
TERMINAL
F
F
OO
N
INDOOR UNIT ON/OFF SWITCH
(INSIDE)
11-9/64(283mm)
BOTTOM
ROOM TEMP. THERMISTOR
FLAPS
GAS PIPE
φ
3/8(
φ
9.5mm) CuT
(INSIDE)
DRAIN HOSE
(THE LENGTH OF PIPE OUTSIDE
(CONNECTING PART
THE UNIT : ABOUT 15-23/64(390mm))
I.D.
F
F
O
O
N
LIQUID PIPE
φ
1/4(
φ
6.4mm) CuT
O.D.
φ
9/16(
φ
14mm)
φ
5/8(
φ
16mm)
(THE LENGTH OF PIPE OUTSIDE
THE HOSE LENGTH OF OUTSIDE
THE UNIT : ABOUT 17-21/64(440mm))
THE UNIT IS ABOUT 17-23/32(450mm))
30-5/16(770mm)
MODEL NAME
SIGNAL TRANSMITTER
15/64(6mm)
21-39/64(549mm)
5/8(16mm)
PLATE
3-31/32(101mm)
11/16(18mm)2-5/16(58mm)
BLADE ANGLE
6-49/64(172mm)
UP/DOWN (AUTOMATIC)
11-9/64(283mm)
1-5/8(41.3mm)
COOLING HEATINGDRY
15°
45°
45°
2-9/64(54.5mm) 2-1/8(54mm)
45°
1-5/8(41.3mm)
7-3/8(187mm)
FAN
WALL HOLE FOR EMBEDDED PIPING
RIGHT/LEFT (MANUAL)
φ
2-9/16(
φ
65mm) HOLE
WALL HOLE
φ
2-9/16(
φ
65mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
WIRELESS REMOTE CONTROLLER
45°
45°
45°
ARC452A19
3D065951C
AIR FLOW
(
INDOOR
)
(
FOR PERFORMANCE AND MAINTENANCE
)
THE MARK
(
®
)
SHOWS PIPING DIRECTION
REARREAR
41-5/16
(
1050
)
LEFT
RIGHT
(
SPACE FOR MAINTENANCE
)
MIN.1-3/16
(
30
)
MIN.1-15/16
(
50
)
MIN.1-15/16
(
50
)
INCLUDING
(
SPACE FOR MAINTENANCE
)
)
INSTALLATION PLATE
(
(SPACE FOR PERFORMANCE)
REQUIRED SPACE
9-7/16
(
240
)
9-3/8
(
238
)
OPERATION LAMP
MODEL NAME
SIGNAL RECEIVER
PLATE
INDOOR UNIT ON/OFF
SWITCH
TERMINAL BLOCK WITH
GROUND TERMINAL
ROOM TEMP. THERMISTOR
(
INSIDE
)
11-7/16
(
290
)
(
INSIDE
)
TIMER LAMP
DRAIN HOSE FOR VP13
(
CONNECTING PART
I.D.9/16
,
O.D.11/16
)
(
THE HOSE LENGTH OF OUTSIDE
THE UNIT:ABOUT 17-5/16
)
GAS PIPE φ1/2 CuT
(
THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 13-3/8
)
FRONT GRILLE FIXING SCREWS
(
INSIDE
)
FLAPS
LIQUID PIPE φ1/4 CuT
(
THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 15-3/8
)
SIGNAL TRANSMITTER
41-5/16
(
1050
)
2-1/4
(
58
)
3/4
(
18
)
BLADE ANGLES
HORIZONTAL BLADE
2-1/1635-3/16
(
893.5
)
(
30
)
9/16
(
14.5
)
1-3/16
(
AUTOMATIC
)
(
52.5
)
COOLING
HEATING
DRY
(
155.5
)
6-1/18
10°
(
52
)
7-3/8
(
187
)
2-1/16
15°
10°
40°
11-7/16
(
290
)
15°
35°
40°
55°
35°
55°
3-15/16
(
99.5
)
2-3/8
(
60
)
FAN
VERTICAL BLADE
(
MANUAL
)
(
52
)
2-1/16
WIRELESS REMOTE
WALL HOLE
φ3-1/8 HOLE
WALL HOLE FOR
EMBEDDED PIPING
φ3-1/8 HOLE
STANDARD LOCATIONS OF WALL HOLES
CONTROLLER
50°
50°
(
ARC452A20
)
55°
55°
3D070535A