Loading...
Specifications EDUS041111_a
6 Room Air Conditioners K-Series
3. Specifications
3.1 Cooling Only
Note: The data are based on the conditions shown in the table below.
Model
60 Hz, 208 - 230V
Indoor Unit FTXN09KEVJU FTXN12KEVJU
Outdoor Unit RKN09KEVJU RKN12KEVJU
Capacity
Rated (Minimum ~ Nominal)
kW 2.64 (1.30 ~ 2.78) 3.52 (1.3 ~ 3.52)
Btu/h 9,000 (4,400 ~ 9,500) 12,000 (4,400 ~ 12,000)
kcal/h 2,270 (1,120 ~ 2,390) 3,030 (1,120 ~ 3,030)
Running Current (Rated) A 4.4 - 4.0 6.2 - 5.6
Power Consumption Rated (Min.~Max.) W 750 (330 ~ 800) 1,210 (330 ~ 1,210)
Power Factor % 81.9 - 81.5 93.8 - 93.9
EER (Rated) (Max.~Min.)
Btu/h·W
12.0 (13.33 ~ 11.90) 9.90 (13.33 ~ 9.90)
Energy Efficiency SEER 18.0 18.0
Piping
Connections
Liquid in. (mm) 1/4 (6.4) 1/4 (6.4)
Gas in. (mm) 3/8 (9.5) 3/8 (9.5)
Drain in. (mm) 5/8 (15.8) 5/8 (15.8)
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length ft. (m) 65.6 (20) 65.6 (20)
Min. Interunit Piping Length ft. (m) 4.9 (1.5) 4.9 (1.5)
Max. Interunit Height Difference ft. (m) 49.2 (15) 49.2 (15)
Chargeless ft. (m) 32.8 (10) 32.8 (10)
Amount of Additional Charge of Refrigerant oz/ft (g/m) 0.22 (6.2) 0.22 (6.2)
Indoor Unit FTXN09KEVJU FTXN12KEVJU
Front Panel Color White White
Airflow Rate
H
cfm
(m³/min)
325 (9.2) 328 (9.3)
M 244 (6.9) 254 (7.2)
L 162 (4.6) 184 (5.2)
SL 138 (3.9) 152 (4.3)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 16 16
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof
Running Current (Rated) A 0.20 - 0.18 0.20 - 0.18
Power Consumption (Rated) W 40 40
Power Factor % 96.2 - 96.6 96.2 - 96.6
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 11-1/8 × 30-3/8 × 7-3/4 (283 x 770 x 198) 11-1/8 × 30-3/8 × 7-3/4 (283 x 770 x 198)
Packaged Dimensions (H × W × D) in. (mm) 10-1/4× 33-1/4 (845) ×13-1/2 (260 x 845 x 343) 10-1/4× 33-1/4 (845) ×13-1/2 (260 x 845 x 343)
Weight Lbs (kg) 16 (7.3) 16 (7.3)
Gross Weight Lbs (kg) 24 (11) 24 (11)
Operation Sound H / M / L / SL dB(A) 40 / 33 / 26 / 22 42 / 34 / 27 / 23
Sound Power dB(A) 56 58
Outdoor Unit RKN09KEVJU RKN12KEVJU
Casing Color Ivory White Ivory White
Compressor
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Model 1YC23AEXD 1YC23AEXD
Motor Output W 750 750
Refrigerant Oil
Type FVC50K FVC50K
Charge oz (g) 12.5 (354) 12.5 (354)
Refrigerant
Type R-410A R-410A
Charge Lbs (kg) 2.20 (1.0) 2.20 (1.0)
Airflow Rate H
cfm
(m³/min)
921 (26.1) 921 (26.1)
Fan
Type Propeller Propeller
Motor Output W 33 33
Running Current (Rated) A 4.20 - 3.82 6.00 - 5.42
Power Consumption (Rated) W 710 1,170
Power Factor % 81.3 - 80.8 93.8 - 93.9
Starting Current A 5.0 6.2
Dimensions (H × W × D) in. (mm) 21-11/16 × 25-15/16 × 10-3/4 21-11/16 × 25-15/16 × 10-3/4
Packaged Dimensions (H × W × D) in. (mm) 23-5/16 × 30-3/8 × 13-3/4 23-5/16 × 30-3/8 × 13-3/4
Weight Lbs (kg) 66 (30) 66 (30)
Gross Weight Lbs (kg) 76 (34.5) 76 (34.5)
Operation Sound dB(A) 48 50
Sound Power dB(A) 62 64
Drawing No. 3D072555 3D072556
Cooling Piping Length
Indoor ;
80°FDB(27°CDB), 67°FWB(19.4°CWB) Outdoor ; 95°FDB(35°CDB /75°FWB(24°CWB) 25 ft (7.5)
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3