EDUS041111_a Optional Accessories
Room Air Conditioners K-Series 173
13.6 <KPW937B4> Air Direction Adjustment Grille
Before Installation
Name
Shape
1piece
Louver Screws M4×30L
4pieces
Installation manual
1piece
1. Install so that a short circuit is prevented.
2. For the use in snowy regions, avoid installation with the air outlet facing upward. Install so that the air outlet faces
leftward, rightward, or downward.
Snow accumulates in the air outlet of the outdoor unit, causing malfunction of the main body of the outdoor unit.
3.
Be advised that if the fan direction is up, dead leaves and other foreign matter easily accumulates in the exhaust vent.
4. Do not use any screws other than those included.
The prepared hole is
in the front panel.
Prepared hole
Prepared hole
Part A “prepared hole portion” cross-section
(The prepared hole does not go through.)
Prepared hole
pitch 17-1/8”(435mm)
Fan partition
Prepared hole
pitch 435mm
Fan partition
Quantity
Use when installing in a location that meets the following conditions.
When installing near the border to a neighbor’s house
If exhaust blows directly on passers-by because outdoor unit is installed facing a road.
Changing the fan direction of the outdoor unit to prevent it blowing directly on shrubbery, etc.
Installation is possible in the four directions:upward, downward, rightward, and leftward.
First temporarily attach the louver with 4 screws, then check that the angle is correct, and finally tighten the screws fully.
Part A
(see figure below)
Part B
(see figure right)
Installation Procedure
Prepared hole
pitch 435mm
Fan partition
Prepared hole
pitch 17-1/8”(435mm)
Fan partition
Use of an electric
screwdriver is
recommended.
Do not open a hole in the prepared hole portion with
a borer, since this will damage internal parts.
Do not use an electric
screwdriver.
<For models with round outlet vents> <For models with square outlet vents>
a)
Grille grating
b)
Grille grating
The prepared hole is approximately
5/8”(15mm) back from the surface
between the bars of the grille.
( Part B )
The cross-section comes in
two shapes, a
)
and b
).
Prepared hole
Checking the parts
Selection of Installation Location
Installation of Louver
Check the following parts
CAUTION
4P202735-1